Products with ELD "TOGS01"

Below you will find a list of products with the ELD "" obtained from our database, including their available manuals, documentation, and images.

Click the corresponding vendor name to obtain additional information on the manufactorer, as well as contact information for further troubleshooting.

Trimble Oil and Gas ELD - Android

Product Image
Vendor Device Name Model Number Approved Version
Trimble Oil and Gas ServicesTrimble Oil and Gas ELD - Android5530+EnergyTablet1.3.46.1A or Higher
  • Data Transfer and Reporting Procedures

    The solution will use Option 1 - Wireless Data Transfer Mechanism. The ELD will support both the Web Services method and the email Method. To use the Data Transfer mechanism over Email or Web Service the Driver or Official will follow these steps: Driver or Official will use the Options button on the driver overview screen Driver or Official will use the Roadside Inspection button on the drop down This button will navigate the user to a Logs Grid page The Logs Grid page will contain a button labeled "Transmit ELD Data File” Driver or Official will be presented with 2 buttons labelled Email and Web Service respectively. Pressing the Email button will initiate the Email data transfer mechanism. Pressing the Web Services button will initiate the web services data transfer mechanism. Note that the latter will be disabled until the FMCSA has released the URL to send the data to.
  • Malfunctions and Testing

    Power P Device lost power during driving events for a total of 30 min or more over a 24-hour period Engine synchronization E Device lost connection to the ECM (or other data source) for a total of more than 30 min during a 24-hour period Timing T Device is not able to synchronize to UTC Positioning L Device is not able to acquire a valid position measurement within 5 mi of vehicle movement for a total of more than 60 min over a 24 hour period. Data recording R Device is no longer able to record or retain required event data or retrieve locally-stored recorded logs Data transfer S Device continues to fail checks of the roadside transfer mechanism for three days following a Data Transfer Diagnostic Event Other ELD detected O The eFleetSuite application has stopped working or is not responding as expected
  • Certification Statement

    Trimble Oil and Gas ELD - Android certifies based on our completion of the testing procedures provided by the FMCSA in the Electronic Logging Device Test Plan and Procedures document version 2.0 dated 10/17/2016 that 5530+MDT7P and complies with all Federal Motor Carrier Safety Administration (FMCSA) specifications as found in 49 CFR Part 395 for Electronic Logging Devices, Subpart B.Devices, Subpart B.

Trimble Oil and Gas ELD - Android

Product Image
Vendor Device Name Model Number Approved Version
Trimble Oil and Gas ServicesTrimble Oil and Gas ELD - Android5530+EnergyTablet8.3.13A or Higher
  • Data Transfer and Reporting Procedures

    >
  • Malfunctions and Testing

    The solution will use Option 1 - Wireless Data Transfer Mechanism. The ELD will support both the Web Services method and the email Method. To use the Data Transfer mechanism over Email or Web Service the Driver or Official will follow these steps: Driver or Official will use the Options button on the driver overview screen Driver or Official will use the Roadside Inspection button on the drop down This button will navigate the user to a Logs Grid page The Logs Grid page will contain a button labeled "Transmit ELD Data File” Driver or Official will be presented with 2 buttons labelled Email and Web Service respectively. Pressing the Email button will initiate the Email data transfer mechanism. Pressing the Web Services button will initiate the web services data transfer mechanism. Note that the latter will be disabled until the FMCSA has released the URL to send the data to.
  • Certification Statement

    Power P Device lost power during driving events for a total of 30 min or more over a 24-hour period Engine synchronization E Device lost connection to the ECM (or other data source) for a total of more than 30 min during a 24-hour period Timing T Device is not able to synchronize to UTC Positioning L Device is not able to acquire a valid position measurement within 5 mi of vehicle movement for a total of more than 60 min over a 24 hour period. Data recording R Device is no longer able to record or retain required event data or retrieve locally-stored recorded logs Data transfer S Device continues to fail checks of the roadside transfer mechanism for three days following a Data Transfer Diagnostic Event Other ELD detected O The eFleetSuite application has stopped working or is not responding as expected
© ELD.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.