Products with ELD "REL002"

Below you will find a list of products with the ELD "" obtained from our database, including their available manuals, documentation, and images.

Click the corresponding vendor name to obtain additional information on the manufactorer, as well as contact information for further troubleshooting.

Omnitracs One with Relay

Product Image
Vendor Device Name Model Number Approved Version
Omnitracs, LLCOmnitracs One with RelayRelay-Android-Drive5.8 or later
  • Data Transfer and Reporting Procedures

    As part of the ELD Mandate, drivers must be able to present safety officials with a copy of their records of duty status for the current day and the past seven days upon request. Omnitracs One Mobile’s eRODS File Transfer functionality allows drivers to do so using either web services or email, which is available from the HOS Options menu. Drivers must be On Duty and within Bluetooth range of an associated vehicle to use this option. From the HOS Log screen: 1. Select the kabob menu in the upper right corner of the HOS Log screen. The HOS Options menu appears. 2. From the menu, select eRODS File Transfer. The eRODS File Transfer screen appears. 3. Select the Web Services or Email field as the appropriate transfer method specified by the enforcement officer. 4. When provided by the enforcement officer, enter the comment in the Enter a Comment (Optional) field. 5. Select Send. A message stating the eRODS file is being processed appears. 6. When the eRODS file transfer is complete, you receive a notification that the file was either sent successfully or that delivery failed. 7. If the transfer fails, attempt a second time. 8. If the transfer fails both attempts, request that the enforcement officer view the records of duty status on the display.
  • Malfunctions and Testing

    If you receive any of the following errors or malfunctions on your ELD you are required to keep paper logs until the malfunction has been corrected. The Omnitracs system immediately notifies the carrier of the malfunction without driver intervention. •Power - An ELD must be powered and function within one minute of the vehicle’s engine receiving power and remain powered for as long as the vehicle’s engine stays powered. • Engine Synchronization - An ELD is required to establish a link to the engine ECM and monitor its connectivity to the engine ECM and its ability to retrieve the vehicle parameters. • Timing - The ELD must cross-check its compliance with the external UTC source and must record any timing compliance malfunction. • Positioning - An ELD must monitor the availability of position measurements meeting the listed accuracy requirements and track the distance and time from the last valid measured point. • Data Recording - An ELD must monitor its storage capacity and integrity and must detect a data recording compliance malfunction if it can no longer record or retain required events. • Data Transfer - An ELD must implement in service monitoring functions to verify that the data transfer mechanism(s) are continuing to function properly. • Other - Any other ELD-detected malfunction such as Bluetooth, relay, etc.
  • Certification Statement

    Omnitracs has distributed and supported AOBRDs in the marketplace since 1989 and has developed testing processes that would assess all areas of the compliance requirements for 49CFR 395.8 and 49CFR 395.15. We have a quality assurance process that follows the creation of story cards for each section of the ELD Mandate specifications. This QA process has been standard operating procedure for Omnitracs and has increased with the ELD mandate requirements. We have used the ELD Testing document issued by FMCSA as a reference to ensure that our testing parallels or exceeds the requirements. Additionally, tests have been created that evaluate fringe cases that are not included in the FMCSA document. Omnitracs employs automated script testing processes for testing of individual elements to ensure consistent and repeatable testing as well the ability to add fringe case scenarios to ensure that in each section of the ELD Mandate, compliance is achieved. We have modified our product through variance changes in the vehicle ECM, changes by OEM and SAE standards, and maintained compliance to ensure that we are continually able to supply information from the ECM. This has ensured that we comply with all the data capture and motion detection requirements specified in the ELD Mandate for the engine ECM. Our testing process includes testing in actual CMV class 6- 8 vehicles as well as using vehicle ECM simulators in testing labs. We additionally use GPS simulators to validate recovery and diagnostics for various situations that can occur in vehicles or environments when GPS may be compromised. With this and other testing processes we are able to test each requirement for diagnostics and malfunctions as required by the ELD Mandate specifications. For eRODS transfer we have provided to Volpe an eRODS test file requested by FMCSA and that file has been accepted. We currently use the FMCSA provided Validator and Web Service access for eRODS transfer to validate the transfer of ELD logs to inspectors as required. Additionally, Omnitracs has developed a 24-Hour monitoring system for eRODS transfer. Omnitracs captures statistics by method of transfer for each individual product certified. This data can be reviewed for various time periods and any failures are identified with the error indicated. We have used this data to notify the FMCSA and Volpe of conditions impacting the transfer process. Omnitracs information security program is based on NIST 800-53 Revision 4. We have ensured that the specified additional security requirements referenced in the regulation for PKI, FIPS, and other NIST specifications have been achieved for compliance to support eRODS transfer. Under penalties of perjury, I, Michael Ahart, hereby certify on behalf of Omnitracs, LLC that the ELD model REL002 and its software complies with FMCSA regulations (ELD Rule).

Omnitracs One with Relay

Product Image
Vendor Device Name Model Number Approved Version
Omnitracs, LLCOmnitracs One with RelayRelay-Android-Drive6.2 or later
  • Data Transfer and Reporting Procedures

    > Telematic (Web Service)
  • Malfunctions and Testing

    As part of the ELD Mandate, drivers must be able to present safety officials with a copy of their records of duty status for the current day and the past seven days upon request. Omnitracs One Mobile’s eRODS File Transfer functionality allows drivers to do so using either web services or email, which is available from the HOS Options menu. Drivers must be On Duty and within Bluetooth range of an associated vehicle to use this option. From the HOS Log screen: 1. Select the kabob menu in the upper right corner of the HOS Log screen. The HOS Options menu appears. 2. From the menu, select eRODS File Transfer. The eRODS File Transfer screen appears. 3. Select the Web Services or Email field as the appropriate transfer method specified by the enforcement officer. 4. When provided by the enforcement officer, enter the comment in the Enter a Comment (Optional) field. 5. Select Send. A message stating the eRODS file is being processed appears. 6. When the eRODS file transfer is complete, you receive a notification that the file was either sent successfully or that delivery failed. 7. If the transfer fails, attempt a second time. 8. If the transfer fails both attempts, request that the enforcement officer view the records of duty status on the display.
  • Certification Statement

    If you receive any of the following errors or malfunctions on your ELD you are required to keep paper logs until the malfunction has been corrected. The Omnitracs system immediately notifies the carrier of the malfunction without driver intervention. •Power - An ELD must be powered and function within one minute of the vehicle’s engine receiving power and remain powered for as long as the vehicle’s engine stays powered. • Engine Synchronization - An ELD is required to establish a link to the engine ECM and monitor its connectivity to the engine ECM and its ability to retrieve the vehicle parameters. • Timing - The ELD must cross-check its compliance with the external UTC source and must record any timing compliance malfunction. • Positioning - An ELD must monitor the availability of position measurements meeting the listed accuracy requirements and track the distance and time from the last valid measured point. • Data Recording - An ELD must monitor its storage capacity and integrity and must detect a data recording compliance malfunction if it can no longer record or retain required events. • Data Transfer - An ELD must implement in service monitoring functions to verify that the data transfer mechanism(s) are continuing to function properly. • Other - Any other ELD-detected malfunction such as Bluetooth, relay, etc.

Omnitracs One with Relay

Product Image
Vendor Device Name Model Number Approved Version
Omnitracs, LLCOmnitracs One with RelayRelay-Android-Drive6.6 or later
  • Data Transfer and Reporting Procedures

    > Telematic (Web Service)
  • Malfunctions and Testing

    As part of the ELD Mandate, drivers must be able to present safety officials with a copy of their records of duty status for the current day and the past seven days upon request. Omnitracs One Mobile’s eRODS File Transfer functionality allows drivers to do so using either web services or email, which is available from the HOS Options menu. Drivers must be On Duty and within Bluetooth range of an associated vehicle to use this option. From the HOS Log screen: 1. Select the kabob menu in the upper right corner of the HOS Log screen. The HOS Options menu appears. 2. From the menu, select eRODS File Transfer. The eRODS File Transfer screen appears. 3. Select the Web Services or Email field as the appropriate transfer method specified by the enforcement officer. 4. When provided by the enforcement officer, enter the comment in the Enter a Comment (Optional) field. 5. Select Send. A message stating the eRODS file is being processed appears. 6. When the eRODS file transfer is complete, you receive a notification that the file was either sent successfully or that delivery failed. 7. If the transfer fails, attempt a second time. 8. If the transfer fails both attempts, request that the enforcement officer view the records of duty status on the display.
  • Certification Statement

    If you receive any of the following errors or malfunctions on your ELD you are required to keep paper logs until the malfunction has been corrected. The Omnitracs system immediately notifies the carrier of the malfunction without driver intervention. •Power - An ELD must be powered and function within one minute of the vehicle’s engine receiving power and remain powered for as long as the vehicle’s engine stays powered. • Engine Synchronization - An ELD is required to establish a link to the engine ECM and monitor its connectivity to the engine ECM and its ability to retrieve the vehicle parameters. • Timing - The ELD must cross-check its compliance with the external UTC source and must record any timing compliance malfunction. • Positioning - An ELD must monitor the availability of position measurements meeting the listed accuracy requirements and track the distance and time from the last valid measured point. • Data Recording - An ELD must monitor its storage capacity and integrity and must detect a data recording compliance malfunction if it can no longer record or retain required events. • Data Transfer - An ELD must implement in service monitoring functions to verify that the data transfer mechanism(s) are continuing to function properly. • Other - Any other ELD-detected malfunction such as Bluetooth, relay, etc.

Omnitracs One with Relay

Product Image
Vendor Device Name Model Number Approved Version
Omnitracs, LLCOmnitracs One with RelayRelay-Android-Drive6.7 or later
  • Data Transfer and Reporting Procedures

    > Telematic (Web Service)
  • Malfunctions and Testing

    As part of the ELD Mandate, drivers must be able to present safety officials with a copy of their records of duty status for the current day and the past seven days upon request. Omnitracs One Mobile’s eRODS File Transfer functionality allows drivers to do so using either web services or email, which is available from the HOS Options menu. Drivers must be On Duty and within Bluetooth range of an associated vehicle to use this option. From the HOS Log screen: 1. Select the kabob menu in the upper right corner of the HOS Log screen. The HOS Options menu appears. 2. From the menu, select eRODS File Transfer. The eRODS File Transfer screen appears. 3. Select the Web Services or Email field as the appropriate transfer method specified by the enforcement officer. 4. When provided by the enforcement officer, enter the comment in the Enter a Comment (Optional) field. 5. Select Send. A message stating the eRODS file is being processed appears. 6. When the eRODS file transfer is complete, you receive a notification that the file was either sent successfully or that delivery failed. 7. If the transfer fails, attempt a second time. 8. If the transfer fails both attempts, request that the enforcement officer view the records of duty status on the display.
  • Certification Statement

    If you receive any of the following errors or malfunctions on your ELD you are required to keep paper logs until the malfunction has been corrected. The Omnitracs system immediately notifies the carrier of the malfunction without driver intervention. •Power - An ELD must be powered and function within one minute of the vehicle’s engine receiving power and remain powered for as long as the vehicle’s engine stays powered. • Engine Synchronization - An ELD is required to establish a link to the engine ECM and monitor its connectivity to the engine ECM and its ability to retrieve the vehicle parameters. • Timing - The ELD must cross-check its compliance with the external UTC source and must record any timing compliance malfunction. • Positioning - An ELD must monitor the availability of position measurements meeting the listed accuracy requirements and track the distance and time from the last valid measured point. • Data Recording - An ELD must monitor its storage capacity and integrity and must detect a data recording compliance malfunction if it can no longer record or retain required events. • Data Transfer - An ELD must implement in service monitoring functions to verify that the data transfer mechanism(s) are continuing to function properly. • Other - Any other ELD-detected malfunction such as Bluetooth, relay, etc.
© ELD.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.