Products with ELD "OCC001"
- OnCommand(R)-Connection-Electronic-Driver-Log Version 1.1 and higher
- OnCommand(R)-Connection-Electronic-Driver-Log Version 1.1 and higher
- OnCommand(R)-Connection-Electronic-Driver-Log Version 1.1 and higher
- OnCommand(R)-Connection-Electronic-Driver-Log Version 1.1 and higher
Below you will find a list of products with the ELD "OCC001" obtained from our database, including their available manuals, documentation, and images.
Click the corresponding vendor name to obtain additional information on the manufacturer, as well as contact information for further troubleshooting.
OnCommand(R) Connection Electronic Driver Log - Self Revoked as of 1607372132
| Vendor | Device Name | Model Number | Approved Version |
|---|---|---|---|
| | OnCommand(R) Connection Electronic Driver Log | XT6300 or Higher | 1.1 and higher |
Data Transfer and Reporting Procedures
>Malfunctions and Testing
The OnCommand(R) Connection Electronic Driver Log supports wireless data transfer via email and web service. To share logs from today and the last 7 days with an officer, a driver should 1) Select the Inspect menu tab of the app. 2) Click Send Logs. 3) Enter the email address provided by the officer and click Send. OR 1) To let an officer view logs on the driver's phone, he/she can simply click Begin Inspection and hand their phone to the officer.Certification Statement
1. Power Data Diagnostic Event Logged * When does it occur? - When ELD device does not turn on within 1 minute of engine being turned on and remains off while vehicle engine is on. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 2. Power Data Diagnostic Event Cleared * When does it occur? - When ELD device powers on once vehicle engine is turned on it should be logged as a cleared data diagnostic event. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 3. Power compliance malfunction logged * When does it occur? - An ELD will set a power compliance malfunction if the power data diagnostics event (Engine power status, vehicle motion status, vehicle miles engine hours), its onboard sensors and data record history indicates an aggregated in-motion driving time understatement of 30 minutes or more on the ELD over a 24-hour period across all driver profiles, including the unidentified driver profile. * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 4. Power compliance malfunction cleared * When does it occur? - When malfunction has been fixed it should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 5. Engine Synchronization data diagnostic Event Logged * When does it occur? - When ELD can't retrieve values for the following data elements (Engine power, vehicle motion, vehicle miles, engine hours), and record data within 5 seconds of driving event - log as a data diagnostic event…5 seconds from driver moving vehicle * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - We’re not receiving information from your ELD. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 6. Engine Synchronization data diagnostic Event Cleared * When does it occur? - When ELD resumes acquiring updated values this will be logged as a cleared event * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 7. Engine Synchronization Compliance Malfunction Logged * When does it occur? - If connectivity to any of the required data sources (engine power status, vehicle motion status, vehicle miles, cmv position, engine hours, cmv vin, date and time) is lost for more than 30 minutes during a 24-hour period across all driver profiles * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 8. Engine Synchronization Compliance Malfunction Cleared * When does it occur? - When connectivity is restored to all data sourced this should be marked as cleared. * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 9. Timing Compliance Malfunction Logged * When does it occur? - If ELD fails to synchronize with UTC and deviation exceeds 10 minutes must log it as a malfunction * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 10. Timing Compliance Malfunction Cleared * When does it occur? - When synchronization is resolved and deviation does not exceed 10 minutes malfunction should be cleared * What happens in the EDL app when this malfunction occurs? -When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 11. Position Compliance Malfunction logged * When does it occur? - When the ELD device does not acquire vehicle position within 5 miles over a 60min period within 24 hours, the ELD must set and record a positioning compliance malfunction. * What happens in the EDL app when this malfunction occurs? -When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 12. Position Compliance Malfunction cleared * When does it occur? - When ELD resumes obtaining valid position, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 13. Missing Required Data Elements Data Diagnostic Event Logged * When does it occur? - If EDL is unable to record events or capture data to record logs - log missing data elements * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? -We’re not receiving information from your ELD. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 14. Missing Required Data Elements Data Diagnostic Event Cleared * When does it occur? - When ELD can resume capturing any missing required data elements data diagnostic event should be cleared * What happens in the EDL app when this malfunction occurs? -When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 15. Data Recording Compliance Malfunction logged * When does it occur? - An ELD must monitor its storage capacity and detect a data recording compliance malfunction if it can no longer record or retain required events * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 16. Data Recording Compliance Malfunction cleared * When does it occur? - When ELD resumes recording required data and storage is not at capacity, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 17. Unidentified Driving Records Data Diagnostic Event Logged * When does it occur? - If system detects unidentified driving for 30 minutes or more in a 24hr period for any drivers profile, the ELD must detect and record an unidentified driving records data diagnostic event. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger icon on home dashboard screen to be displayed. When driver has not logged in and vehicle is moving, this will trigger a pop-up modal prompting them to log in. * What message will the user see? - Unidentified driving was detected across 1 or more vehicles. We will log this as a malfunction until your carrier assigns drive time. 18. Unidentified Driving Records Data Diagnostic Event Cleared * When does it occur? - When unidentified driving occurs for 15 minutes or less for a profile within 24 hrs and across a 7 day period this diagnostic can be cleared. * What happens in the EDL app when this malfunction occurs? - When user has responded to Unidentified Driving pop-up modal message and has confirmed their driving status, Diagnostic is cleared, icon will not be present on screen * What message will the user see? - Unidentified driving was assigned to your profile. Please log into the EDL app to capture your log hours. 19. Data Transfer Data Diagnostic Event Logged * When does it occur? - An ELD must record a data transfer data diagnostic event when ELD fails to properly allow electronic data transfer (email, bluetooth) when the user initiates transfer. The ELD must monitor each time driver selects the data transfer option. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - We’re unable to transfer the requested information. Please ensure you have network connection and try again. You will continue to receive alerts until this is resolved. 20. Data Transfer Data Diagnostic Event Cleared * When does it occur? - If issue is resolved and data transfer functioning is working properly it should be cleared * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your attempt to transfer data was successful and no longer requires attention. 21. Data Transfer Compliance Malfunction Logged * When does it occur? - If the ELD is still unable to transfer data following the next three consecutive monitoring checks, the ELD must detect a data transfer compliance malfunction. * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - After multiple failed attempts this issue requires immediate attention. Please check your device to repair the issue. You will continue to receive alerts until this has been resolved. 22. Data Transfer Compliance Malfunction Cleared * When does it occur? - Once issue is resolved and can resume transferring data, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your attempt to transfer data was successful and no longer requires attention.
OnCommand(R) Connection Electronic Driver Log - Self Revoked as of 1607372060
| Vendor | Device Name | Model Number | Approved Version |
|---|---|---|---|
| | OnCommand(R) Connection Electronic Driver Log | XT6360 – AT&T 3G | 1.1 and higher |
Data Transfer and Reporting Procedures
>Malfunctions and Testing
The OnCommand(R) Connection Electronic Driver Log supports wireless data transfer via email and web service. To share logs from today and the last 7 days with an officer, a driver should 1) Select the Inspect menu tab of the app. 2) Click Send Logs. 3) Enter the email address provided by the officer and click Send. OR 1) To let an officer view logs on the driver's phone, he/she can simply click Begin Inspection and hand their phone to the officer.Certification Statement
1. Power Data Diagnostic Event Logged * When does it occur? - When ELD device does not turn on within 1 minute of engine being turned on and remains off while vehicle engine is on. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 2. Power Data Diagnostic Event Cleared * When does it occur? - When ELD device powers on once vehicle engine is turned on it should be logged as a cleared data diagnostic event. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 3. Power compliance malfunction logged * When does it occur? - An ELD will set a power compliance malfunction if the power data diagnostics event (Engine power status, vehicle motion status, vehicle miles engine hours), its onboard sensors and data record history indicates an aggregated in-motion driving time understatement of 30 minutes or more on the ELD over a 24-hour period across all driver profiles, including the unidentified driver profile. * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 4. Power compliance malfunction cleared * When does it occur? - When malfunction has been fixed it should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 5. Engine Synchronization data diagnostic Event Logged * When does it occur? - When ELD can't retrieve values for the following data elements (Engine power, vehicle motion, vehicle miles, engine hours), and record data within 5 seconds of driving event - log as a data diagnostic event…5 seconds from driver moving vehicle * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - We’re not receiving information from your ELD. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 6. Engine Synchronization data diagnostic Event Cleared * When does it occur? - When ELD resumes acquiring updated values this will be logged as a cleared event * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 7. Engine Synchronization Compliance Malfunction Logged * When does it occur? - If connectivity to any of the required data sources (engine power status, vehicle motion status, vehicle miles, cmv position, engine hours, cmv vin, date and time) is lost for more than 30 minutes during a 24-hour period across all driver profiles * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 8. Engine Synchronization Compliance Malfunction Cleared * When does it occur? - When connectivity is restored to all data sourced this should be marked as cleared. * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 9. Timing Compliance Malfunction Logged * When does it occur? - If ELD fails to synchronize with UTC and deviation exceeds 10 minutes must log it as a malfunction * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 10. Timing Compliance Malfunction Cleared * When does it occur? - When synchronization is resolved and deviation does not exceed 10 minutes malfunction should be cleared * What happens in the EDL app when this malfunction occurs? -When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 11. Position Compliance Malfunction logged * When does it occur? - When the ELD device does not acquire vehicle position within 5 miles over a 60min period within 24 hours, the ELD must set and record a positioning compliance malfunction. * What happens in the EDL app when this malfunction occurs? -When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 12. Position Compliance Malfunction cleared * When does it occur? - When ELD resumes obtaining valid position, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 13. Missing Required Data Elements Data Diagnostic Event Logged * When does it occur? - If EDL is unable to record events or capture data to record logs - log missing data elements * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? -We’re not receiving information from your ELD. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 14. Missing Required Data Elements Data Diagnostic Event Cleared * When does it occur? - When ELD can resume capturing any missing required data elements data diagnostic event should be cleared * What happens in the EDL app when this malfunction occurs? -When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 15. Data Recording Compliance Malfunction logged * When does it occur? - An ELD must monitor its storage capacity and detect a data recording compliance malfunction if it can no longer record or retain required events * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 16. Data Recording Compliance Malfunction cleared * When does it occur? - When ELD resumes recording required data and storage is not at capacity, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 17. Unidentified Driving Records Data Diagnostic Event Logged * When does it occur? - If system detects unidentified driving for 30 minutes or more in a 24hr period for any drivers profile, the ELD must detect and record an unidentified driving records data diagnostic event. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger icon on home dashboard screen to be displayed. When driver has not logged in and vehicle is moving, this will trigger a pop-up modal prompting them to log in. * What message will the user see? - Unidentified driving was detected across 1 or more vehicles. We will log this as a malfunction until your carrier assigns drive time. 18. Unidentified Driving Records Data Diagnostic Event Cleared * When does it occur? - When unidentified driving occurs for 15 minutes or less for a profile within 24 hrs and across a 7 day period this diagnostic can be cleared. * What happens in the EDL app when this malfunction occurs? - When user has responded to Unidentified Driving pop-up modal message and has confirmed their driving status, Diagnostic is cleared, icon will not be present on screen * What message will the user see? - Unidentified driving was assigned to your profile. Please log into the EDL app to capture your log hours. 19. Data Transfer Data Diagnostic Event Logged * When does it occur? - An ELD must record a data transfer data diagnostic event when ELD fails to properly allow electronic data transfer (email, bluetooth) when the user initiates transfer. The ELD must monitor each time driver selects the data transfer option. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - We’re unable to transfer the requested information. Please ensure you have network connection and try again. You will continue to receive alerts until this is resolved. 20. Data Transfer Data Diagnostic Event Cleared * When does it occur? - If issue is resolved and data transfer functioning is working properly it should be cleared * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your attempt to transfer data was successful and no longer requires attention. 21. Data Transfer Compliance Malfunction Logged * When does it occur? - If the ELD is still unable to transfer data following the next three consecutive monitoring checks, the ELD must detect a data transfer compliance malfunction. * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - After multiple failed attempts this issue requires immediate attention. Please check your device to repair the issue. You will continue to receive alerts until this has been resolved. 22. Data Transfer Compliance Malfunction Cleared * When does it occur? - Once issue is resolved and can resume transferring data, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your attempt to transfer data was successful and no longer requires attention.
OnCommand(R) Connection Electronic Driver Log - Self Revoked as of 1607372008
| Vendor | Device Name | Model Number | Approved Version |
|---|---|---|---|
| | OnCommand(R) Connection Electronic Driver Log | XT6372 – VZW LTE | 1.1 and higher |
Data Transfer and Reporting Procedures
>Malfunctions and Testing
The OnCommand(R) Connection Electronic Driver Log supports wireless data transfer via email and web service. To share logs from today and the last 7 days with an officer, a driver should 1) Select the Inspect menu tab of the app. 2) Click Send Logs. 3) Enter the email address provided by the officer and click Send. OR 1) To let an officer view logs on the driver's phone, he/she can simply click Begin Inspection and hand their phone to the officer.Certification Statement
1. Power Data Diagnostic Event Logged * When does it occur? - When ELD device does not turn on within 1 minute of engine being turned on and remains off while vehicle engine is on. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 2. Power Data Diagnostic Event Cleared * When does it occur? - When ELD device powers on once vehicle engine is turned on it should be logged as a cleared data diagnostic event. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 3. Power compliance malfunction logged * When does it occur? - An ELD will set a power compliance malfunction if the power data diagnostics event (Engine power status, vehicle motion status, vehicle miles engine hours), its onboard sensors and data record history indicates an aggregated in-motion driving time understatement of 30 minutes or more on the ELD over a 24-hour period across all driver profiles, including the unidentified driver profile. * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 4. Power compliance malfunction cleared * When does it occur? - When malfunction has been fixed it should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 5. Engine Synchronization data diagnostic Event Logged * When does it occur? - When ELD can't retrieve values for the following data elements (Engine power, vehicle motion, vehicle miles, engine hours), and record data within 5 seconds of driving event - log as a data diagnostic event…5 seconds from driver moving vehicle * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - We’re not receiving information from your ELD. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 6. Engine Synchronization data diagnostic Event Cleared * When does it occur? - When ELD resumes acquiring updated values this will be logged as a cleared event * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 7. Engine Synchronization Compliance Malfunction Logged * When does it occur? - If connectivity to any of the required data sources (engine power status, vehicle motion status, vehicle miles, cmv position, engine hours, cmv vin, date and time) is lost for more than 30 minutes during a 24-hour period across all driver profiles * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 8. Engine Synchronization Compliance Malfunction Cleared * When does it occur? - When connectivity is restored to all data sourced this should be marked as cleared. * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 9. Timing Compliance Malfunction Logged * When does it occur? - If ELD fails to synchronize with UTC and deviation exceeds 10 minutes must log it as a malfunction * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 10. Timing Compliance Malfunction Cleared * When does it occur? - When synchronization is resolved and deviation does not exceed 10 minutes malfunction should be cleared * What happens in the EDL app when this malfunction occurs? -When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 11. Position Compliance Malfunction logged * When does it occur? - When the ELD device does not acquire vehicle position within 5 miles over a 60min period within 24 hours, the ELD must set and record a positioning compliance malfunction. * What happens in the EDL app when this malfunction occurs? -When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 12. Position Compliance Malfunction cleared * When does it occur? - When ELD resumes obtaining valid position, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 13. Missing Required Data Elements Data Diagnostic Event Logged * When does it occur? - If EDL is unable to record events or capture data to record logs - log missing data elements * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? -We’re not receiving information from your ELD. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 14. Missing Required Data Elements Data Diagnostic Event Cleared * When does it occur? - When ELD can resume capturing any missing required data elements data diagnostic event should be cleared * What happens in the EDL app when this malfunction occurs? -When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 15. Data Recording Compliance Malfunction logged * When does it occur? - An ELD must monitor its storage capacity and detect a data recording compliance malfunction if it can no longer record or retain required events * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 16. Data Recording Compliance Malfunction cleared * When does it occur? - When ELD resumes recording required data and storage is not at capacity, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 17. Unidentified Driving Records Data Diagnostic Event Logged * When does it occur? - If system detects unidentified driving for 30 minutes or more in a 24hr period for any drivers profile, the ELD must detect and record an unidentified driving records data diagnostic event. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger icon on home dashboard screen to be displayed. When driver has not logged in and vehicle is moving, this will trigger a pop-up modal prompting them to log in. * What message will the user see? - Unidentified driving was detected across 1 or more vehicles. We will log this as a malfunction until your carrier assigns drive time. 18. Unidentified Driving Records Data Diagnostic Event Cleared * When does it occur? - When unidentified driving occurs for 15 minutes or less for a profile within 24 hrs and across a 7 day period this diagnostic can be cleared. * What happens in the EDL app when this malfunction occurs? - When user has responded to Unidentified Driving pop-up modal message and has confirmed their driving status, Diagnostic is cleared, icon will not be present on screen * What message will the user see? - Unidentified driving was assigned to your profile. Please log into the EDL app to capture your log hours. 19. Data Transfer Data Diagnostic Event Logged * When does it occur? - An ELD must record a data transfer data diagnostic event when ELD fails to properly allow electronic data transfer (email, bluetooth) when the user initiates transfer. The ELD must monitor each time driver selects the data transfer option. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - We’re unable to transfer the requested information. Please ensure you have network connection and try again. You will continue to receive alerts until this is resolved. 20. Data Transfer Data Diagnostic Event Cleared * When does it occur? - If issue is resolved and data transfer functioning is working properly it should be cleared * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your attempt to transfer data was successful and no longer requires attention. 21. Data Transfer Compliance Malfunction Logged * When does it occur? - If the ELD is still unable to transfer data following the next three consecutive monitoring checks, the ELD must detect a data transfer compliance malfunction. * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - After multiple failed attempts this issue requires immediate attention. Please check your device to repair the issue. You will continue to receive alerts until this has been resolved. 22. Data Transfer Compliance Malfunction Cleared * When does it occur? - Once issue is resolved and can resume transferring data, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your attempt to transfer data was successful and no longer requires attention.
OnCommand(R) Connection Electronic Driver Log - Self Revoked as of 1607372052
| Vendor | Device Name | Model Number | Approved Version |
|---|---|---|---|
| | OnCommand(R) Connection Electronic Driver Log | XT6376 – AT&T LTE/3G | 1.1 and higher |
Data Transfer and Reporting Procedures
>Malfunctions and Testing
The OnCommand(R) Connection Electronic Driver Log supports wireless data transfer via email and web service. To share logs from today and the last 7 days with an officer, a driver should 1) Select the Inspect menu tab of the app. 2) Click Send Logs. 3) Enter the email address provided by the officer and click Send. OR 1) To let an officer view logs on the driver's phone, he/she can simply click Begin Inspection and hand their phone to the officer.Certification Statement
1. Power Data Diagnostic Event Logged * When does it occur? - When ELD device does not turn on within 1 minute of engine being turned on and remains off while vehicle engine is on. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 2. Power Data Diagnostic Event Cleared * When does it occur? - When ELD device powers on once vehicle engine is turned on it should be logged as a cleared data diagnostic event. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 3. Power compliance malfunction logged * When does it occur? - An ELD will set a power compliance malfunction if the power data diagnostics event (Engine power status, vehicle motion status, vehicle miles engine hours), its onboard sensors and data record history indicates an aggregated in-motion driving time understatement of 30 minutes or more on the ELD over a 24-hour period across all driver profiles, including the unidentified driver profile. * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 4. Power compliance malfunction cleared * When does it occur? - When malfunction has been fixed it should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 5. Engine Synchronization data diagnostic Event Logged * When does it occur? - When ELD can't retrieve values for the following data elements (Engine power, vehicle motion, vehicle miles, engine hours), and record data within 5 seconds of driving event - log as a data diagnostic event…5 seconds from driver moving vehicle * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - We’re not receiving information from your ELD. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 6. Engine Synchronization data diagnostic Event Cleared * When does it occur? - When ELD resumes acquiring updated values this will be logged as a cleared event * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 7. Engine Synchronization Compliance Malfunction Logged * When does it occur? - If connectivity to any of the required data sources (engine power status, vehicle motion status, vehicle miles, cmv position, engine hours, cmv vin, date and time) is lost for more than 30 minutes during a 24-hour period across all driver profiles * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 8. Engine Synchronization Compliance Malfunction Cleared * When does it occur? - When connectivity is restored to all data sourced this should be marked as cleared. * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 9. Timing Compliance Malfunction Logged * When does it occur? - If ELD fails to synchronize with UTC and deviation exceeds 10 minutes must log it as a malfunction * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 10. Timing Compliance Malfunction Cleared * When does it occur? - When synchronization is resolved and deviation does not exceed 10 minutes malfunction should be cleared * What happens in the EDL app when this malfunction occurs? -When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 11. Position Compliance Malfunction logged * When does it occur? - When the ELD device does not acquire vehicle position within 5 miles over a 60min period within 24 hours, the ELD must set and record a positioning compliance malfunction. * What happens in the EDL app when this malfunction occurs? -When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 12. Position Compliance Malfunction cleared * When does it occur? - When ELD resumes obtaining valid position, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 13. Missing Required Data Elements Data Diagnostic Event Logged * When does it occur? - If EDL is unable to record events or capture data to record logs - log missing data elements * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? -We’re not receiving information from your ELD. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 14. Missing Required Data Elements Data Diagnostic Event Cleared * When does it occur? - When ELD can resume capturing any missing required data elements data diagnostic event should be cleared * What happens in the EDL app when this malfunction occurs? -When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? -Your ELD connection is fully restored. We will resume auto recording your hour logs. 15. Data Recording Compliance Malfunction logged * When does it occur? - An ELD must monitor its storage capacity and detect a data recording compliance malfunction if it can no longer record or retain required events * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? -Your ELD is not working properly. Please call (888) 661-6272 and choose option 3 for Support. You must switch to paper logs until this is resolved. 16. Data Recording Compliance Malfunction cleared * When does it occur? - When ELD resumes recording required data and storage is not at capacity, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your ELD connection is fully restored. We will resume auto recording your hour logs. 17. Unidentified Driving Records Data Diagnostic Event Logged * When does it occur? - If system detects unidentified driving for 30 minutes or more in a 24hr period for any drivers profile, the ELD must detect and record an unidentified driving records data diagnostic event. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger icon on home dashboard screen to be displayed. When driver has not logged in and vehicle is moving, this will trigger a pop-up modal prompting them to log in. * What message will the user see? - Unidentified driving was detected across 1 or more vehicles. We will log this as a malfunction until your carrier assigns drive time. 18. Unidentified Driving Records Data Diagnostic Event Cleared * When does it occur? - When unidentified driving occurs for 15 minutes or less for a profile within 24 hrs and across a 7 day period this diagnostic can be cleared. * What happens in the EDL app when this malfunction occurs? - When user has responded to Unidentified Driving pop-up modal message and has confirmed their driving status, Diagnostic is cleared, icon will not be present on screen * What message will the user see? - Unidentified driving was assigned to your profile. Please log into the EDL app to capture your log hours. 19. Data Transfer Data Diagnostic Event Logged * When does it occur? - An ELD must record a data transfer data diagnostic event when ELD fails to properly allow electronic data transfer (email, bluetooth) when the user initiates transfer. The ELD must monitor each time driver selects the data transfer option. * What happens in the EDL app when this malfunction occurs? - When Diagnostic is present, trigger notification banner and icon on home dashboard screen * What message will the user see? - We’re unable to transfer the requested information. Please ensure you have network connection and try again. You will continue to receive alerts until this is resolved. 20. Data Transfer Data Diagnostic Event Cleared * When does it occur? - If issue is resolved and data transfer functioning is working properly it should be cleared * What happens in the EDL app when this malfunction occurs? - When Diagnostic is cleared, trigger notification banner for diagnostic cleared and icon will not be present on screen * What message will the user see? - Your attempt to transfer data was successful and no longer requires attention. 21. Data Transfer Compliance Malfunction Logged * When does it occur? - If the ELD is still unable to transfer data following the next three consecutive monitoring checks, the ELD must detect a data transfer compliance malfunction. * What happens in the EDL app when this malfunction occurs? - When malfunction is present, ELD will trigger icon display of malfunction icon on home screen, present notification banner, show record on reporting file as one of the following: "MalfunctionIndicatorStatus":"1" 0 (no active malfunction) or 1 (at least one active malfunction). * What message will the user see? - After multiple failed attempts this issue requires immediate attention. Please check your device to repair the issue. You will continue to receive alerts until this has been resolved. 22. Data Transfer Compliance Malfunction Cleared * When does it occur? - Once issue is resolved and can resume transferring data, malfunction should be cleared * What happens in the EDL app when this malfunction occurs? - When malfunction is cleared, icon will be removed from home dashboard, notification banner will be triggered * What message will the user see? - Your attempt to transfer data was successful and no longer requires attention.