Products with ELD "57215A"
Below you will find a list of products with the ELD "" obtained from our database, including their available manuals, documentation, and images.
Click the corresponding vendor name to obtain additional information on the manufactorer, as well as contact information for further troubleshooting.
Vnomics ELD - Self Revoked as of 1646152115

Vendor | Device Name | Model Number | Approved Version |
---|---|---|---|
| Vnomics ELD | ELD-572 | 15 or later |
Data Transfer and Reporting Procedures
>Malfunctions and Testing
Vnomics supports Telematics transfers. Step by Step: Press “Roadside Inspection” Press “Webservice” or “Email” Add a comment if directed by Enforcement Press “Confirm and Send Logs”Certification Statement
Power Malfunction: ELD is running and vehicle engine is running, but no power-up event was found. It is assumed that the vehicle may have been in motion without recording events, so a Power Malfunction is set. The power malfunction is reset when the next power-up event is written. Engine Sync Malfunction: data connection to the vehicle data bus has been lost for more than 30 minutes aggregated over previous 24 hours Timing Malfunction: ELD has detected that its time is off by more than 10 minutes from actual time Positioning Malfunction: ELD has lost GPS connection when the vehicle has moved more than 5 miles. The malfunction is set if GPS has been missing for than 60 minutes over the past day. Data Recording Malfunction: ELD is unable to write new events and/or read previously recorded logs Data Transfer Unavailable: ELD has detected that the Vnomics backend cannot connect to FMCSA email or webservices. Driver is advised to use display to review logs with Enforcement.